Resolving Ruby EventMachine reactor block due to synchronous I/O operations Under Peak Event Traffic on Linode
Diagnosing EventMachine Reactor Stalls Under Load When an EventMachine-based Ruby application experiences reactor stalls under peak traffic on a Linode instance, the root cause is almost invariably a synchronous I/O operation blocking the event loop. EventMachine, by design, relies on a single-threaded, non-blocking I/O model. Any operation that ties up the CPU or waits for […]